My Freezer Is Over Cooling?
If you find a lot of dust accumulated on the coils, plan to clean them once or twice a year to keep the refrigerator properly cooled. To temporarily put the refrigerator into operation, remove the back panel of the freezer and remove all accumulated frost (it is better to pour hot water over the coils). If the freezer is cold, but the refrigerator is hot and the evaporator coils are frozen, the problem may be in the defrost system. However, if the defrost system is not working properly, the evaporator coils will freeze, leaving the Samsung refrigerator hot but cold in the freezer.
A defrost problem can occur if the back of the freezer, where the evaporator coil is located, is severely frozen. Frost formation only on the back of the freezer, where the evaporator coil is located, indicates a problem with the defrost cycle. If the fan and compressor are running, but the refrigerator is too cold, it may be a symptom of a malfunctioning temperature controller. In this case, it will not detect the actual temperature of the refrigerator and may cause the fan and compressor to run too often, causing the refrigerator to become too cold.
The sensor should send temperature readings from the refrigerator to the control board, but if it’s faulty, the refrigerator is most likely not cooling. A temperature sensor / thermometer monitors the temperature of the freezer and refrigerator and adjusts the fans, damper and compressor accordingly.
If the environment is too cold, the freezer may not work long enough to maintain its temperature. If hot, humid air constantly enters the freezer, it will have to work much harder to maintain the desired temperature in the freezer. This can increase energy costs and cause problems with ice inside the freezer. A defective thermostat does not transfer energy to the cooling system and the freezer compartment does not cool.
If your refrigerator is too cold at its lowest level, the problem could be a faulty temperature controller. Often times when the cold control is faulty, the freezer and refrigerator become too cold and you hear the compressor running longer than it should.
If the temperature is still too low, move the air regulator to a cold freezer or warm refrigerator. Make sure the appliance controls are set to 0 ° F (-18 ° C) for the freezer and 37 ° F (3 ° C) for the refrigerator. Make sure the temperature in the freezer is about 0 ° F (-18 ° C) and the temperature in the refrigerator is about 37 ° F (3 ° C). The freezer temperature may be too low if the frost is light, snowy and seems to be all over the place.
If the defrost heater is not turned on, frost will form on the coil, and eventually air will not be able to pass through the coil to cool the freezer or refrigerator. For this reason, the defrost thermostat must ensure that the coil is sufficiently cold. If the temperature is too high or too low, the control panel will turn the compressor on or off accordingly. Air leakage in the door seal will cause the control system to continue to require cooling.
If the door stays open for too long – a lot of humid air can enter if the freezer compartment is left open while refilling. Frost build-up in the freezer can also block the air vent, reducing or preventing cold air from entering the refrigerator. When the refrigerator is turned off, air from the freezer compartment can enter the bottom of the refrigerator, causing very cold temperatures and freezing vegetables and fruits stored in the drawer. The fresh food side of the LG refrigerator is cooled by letting air from the freezer compartment through the flap.
If the freezer compartment is cold and the refrigerator is hot, the damper control device may be blocked or damaged. The damper is a part of the refrigerator/freezer and is used to control the amount of cold air moving from the freezer to the refrigerator. If you cannot feel fresh air entering the refrigerator (but you know that the evaporator fan is working), the damper is likely to be stuck or in the closed position.
If the flap is not working properly, it can create excess air that will enter the refrigerator compartment, causing the temperature to gradually drop. If the flap control assembly does not open properly, cold air will not enter the refrigerator and you will feel that the Samsung refrigerator is not cooling down. If this part does not open and close easily, it may cause too much cold air to enter the refrigerator and create a refrigerator that is too cold.
Typically, there are two control knobs in the refrigerator: one is for regulating the cold, and this is the thermostat, and the other knob adjusts the air flow between the compartments.
Basically, it is a unit needed to regulate the amount of chilled air entering the refrigerator from the freezer. If it does not open properly, the refrigerator will not get enough cold air. If this door is locked or broken, it will not allow enough cold air to pass through to maintain the proper temperature.
If the fan in your refrigerator is running, the airflow in the refrigerator seems to be unlocked and the settings are correct, but you are still getting very cold temperatures, you may have a cold control problem. If everything in your fridge is freezing and looks more like a freezer than a refrigerator and the controls seem to be tweaked at some point, the problem is most likely not caused by airflow issues. When the refrigerator is not cold but the freezer is, the problem is likely that one of the mechanisms in your refrigerator is not working properly. Even if the rest of the refrigerator is working properly, if the magnetic seals on the doors, also called “door seals,” are defective, fresh air inside the refrigerator may escape.
Over time, coils that are not in the sealed unit can become covered with dust, hair, or pet hair, reducing their ability to keep cold air in the refrigerator. When these coils become covered with dust or other dirt, it makes the refrigerator work harder and harder to maintain the optimum temperature. Even dirty evaporator coils can have problems transferring heat or cold efficiently.
A small fan and motor are installed near the evaporator to help draw air over the coils and circulate it in the refrigerator and freezer. Both sides of the LG refrigerator are cooled by cold air, which is drawn into the evaporator coils by a fan that circulates the air in both directions. In a parallel fridge-freezer, air flows through the vent at the top of the fresh food compartment and then returns to the freezer at the bottom of the freezer. The side-by-side or top and bottom freezer and refrigerator should keep the food inside at the optimum temperature, but there are times when problems arise behind the refrigerator when it gets too cold.
If you still are experiencing freezer over cooling problems and need freezer repair in Oklahoma City be sure and contact Appliance Repair OKC Services. Call 405-378-4566 or visit our website at https://okcappliance.com or also out Google business page at https://cutt.ly/YEnc8qk. Call for repairs today!